X線診断領域におけるガラス線量計(GD-352M)の諸特性
https://gchs.repo.nii.ac.jp/records/29
https://gchs.repo.nii.ac.jp/records/29b6dd4d27-c8be-417d-a332-d694fab897ff
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-02-20 | |||||
タイトル | ||||||
タイトル | X線診断領域におけるガラス線量計(GD-352M)の諸特性 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 蛍光ガラス線量計 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | エネルギー依存性 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ガラス素子 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Radio photo luminescence glass dosimeter | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Energy dependency | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Glass element | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
河原田, 泰尋
× 河原田, 泰尋× 阿部, 真衣子× 小澤, 慶子× 小野, 絵理× 根岸, 徹× 長島, 宏幸× 五十嵐, 博× kawaharada, Yasuhiro× Abe, Maiko× Ozawa, Keiko× Ono, Eri× Negishi, Toru× Nagashima, Hiroyuki× Igarashi, Hiroshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 目的:地域施設のX線検査被ばく線量の測定をガラス線量計により行うことを目的に,ガラス線量計の特性を調べ有用性と留意点について検討した.方法:ガラス素子(GD-352)の感度均一性,素子個々の繰り返し再現性,線量直線性,エネルギー特性について電離箱線量計と比較測定した.また,照射後の経過時間におけるビルドアップの形成とアニーリング後の自然積算線量について調べた.結果:繰り返し再現性は約±5%であった.線量直線性は良いが低線量,低管電圧で測定値のばらつきが大きくなる.補償フィルタによる吸収で感度は25keVで約20%低下し,17keVで約50%低下した.ガラス素子の室温におけるビルドアップは24時間経過すると約98%完了する.自然放射線による蓄積線量は約1.7μGy/日であった.結論:低管電庄と低線量により検査される小児の測定では,測定値のばらつきが大きくなるため注意が必要である.マンモグラフィ領域の使用では,新たなエネルギー補償フィルタ物質と感度の調整が必要である. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Object: To measure the exposure dose of X-ray equipment at our facility, we examined the characteristics of the glass dosimeter, and considered the usefulness and potential hazards associated with this equipment. Methods: An ionization chamber dosimeter was used to measure sensitivity, uniformity, repeatability, reproducibility, dose linearity, and energy characteristics of individual glass dosimetry elements (GD-352). We also studied build up of radiation dose and integral dose over time after annealing. Results : The repetition reproducibility was approximately ±5%. Although the dose linearity was good, dispersion of the measured value increased at low doses and low tube voltages. The compensating filter reduced absorption sensitivity by about 20% at 25 keV and by about 50% at 17 keV. After 24 hours, build up at room temperature for the glass element was approximately 98%. Accumulated dose in terms of natural radiation was approximately 1.7μGy/day. Conclusions: Since dispersion of the measured value increases at low tube voltages and low doses, attention is necessary when using the GD-352 to perform imaging studies of infants. In order to use the GD-352 in mammography, a new energy compensating filter material with increased sensitivity should be developed. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 原著 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 群馬県立県民健康科学大学紀要 3,11-19,2008 | |||||
書誌情報 |
群馬県立県民健康科学大学紀要 巻 3, p. 11-19, 発行日 2008-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1881-0691 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12136570 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
その他のタイトル | ||||||
その他のタイトル | Characteristics of the Glass Dosimeter GD-352M in X-ray Diagnosis | |||||
出版者 | ||||||
出版者 | 群馬県立県民健康科学大学 | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article |