{"created":"2023-06-28T07:20:40.137005+00:00","id":155,"links":{},"metadata":{"_buckets":{"deposit":"b0ffc69f-3bcc-4df5-b499-710879ab189a"},"_deposit":{"created_by":4,"id":"155","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"155"},"status":"published"},"_oai":{"id":"oai:gchs.repo.nii.ac.jp:00000155","sets":["10:11:40"]},"author_link":["948","945","950","954","951","947","953","946","952","949"],"item_3_alternative_title_12":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Verifiable Study of the Status of Bed Peripheral Equipment Used in Nursing Practice Rooms after Disinfection Using a Wiping-type ATP Detector and Microbial Culture"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"58","bibliographicPageStart":"41","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"群馬県立県民健康科学大学紀要"}]}]},"item_3_description_14":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_3_description_3":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"感染症対策としての感染経路は,飛沫感染,空気感染が主であると言われているが MRSA や VRE の場合,患者から医療スタッフを介した接触感染も存在することが指摘されている.この観点から,今回主に,当校の 2F 第 1 看護実習室にて行われている看護技術演習時に使用するベッド周囲の器具,その他の数か所の ATP 値,コンパクトドライ,ぺたんチェックを使用して汚れの程度,細菌,真菌を測定し,どの場所が清浄なのか,どの場所に問題があるのかを洗い出した.看護実習室以外にも測定箇所を広げ,総合的に判断し,その感度についても検討を行った.結果からは,複数の場所について清浄度に問題のある場所が見つかったので,感染予防の観点から消毒の必要性の有無を再検討し,消毒が不十分であったり,方法に問題がある箇所を指摘すると同時に,ATP 検査と細菌のコロニー数との相関関係についても検討した.","subitem_description_type":"Abstract"},{"subitem_description":"Droplet and airborne transmission are said to be the main routes of infection to consider when devising countermeasures against infectious diseases, but infection through contact transmission from medical staff to patients has also been pointed out in the cases of methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococcus. \nThe present study examined the cleanliness of nursing skill training equipment located around the bed in our school’s nursing practice room using adenosine triphosphate (ATP) values and microbial colony counts calculated by the “Compact Dry method” and “Petan check stamp method” at specific locations. We measured the degree of dirt, bacteria, and fungi, and identified which areas were clean and which areas had problems. We expanded the measurement points to include areas other than the nursing practice room, made comprehensive judgments, and examined the sensitivity of the results. \nConsequently, we found multiple areas with cleanliness problems. Therefore, from the perspective of infection prevention, we reexamined whether disinfection was necessary and the relationship between the results of the ATP test and the bacterial colony count.","subitem_description_type":"Abstract"}]},"item_3_description_4":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"報告","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"群馬県立県民健康科学大学紀要18,1-12.(2023)","subitem_description_type":"Other"}]},"item_3_publisher_13":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"群馬県立県民健康科学大学"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1881-0691","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_8":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12136570","subitem_source_identifier_type":"NCID"}]},"item_3_version_type_10":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"青木, 武生"}],"nameIdentifiers":[{"nameIdentifier":"945","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 恵理"}],"nameIdentifiers":[{"nameIdentifier":"946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"髙橋, 美穂子"}],"nameIdentifiers":[{"nameIdentifier":"947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大川, 美千代"}],"nameIdentifiers":[{"nameIdentifier":"948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金谷, 悦子"}],"nameIdentifiers":[{"nameIdentifier":"949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Aoki, Takeo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzuki, Eri","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"951","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takahashi, Mihoko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"952","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohkawa, Michiyo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanaya, Etsuko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"954","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-27"}],"displaytype":"detail","filename":"04 KKG18-Aoki.pdf","filesize":[{"value":"29.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"18-04","url":"https://gchs.repo.nii.ac.jp/record/155/files/04 KKG18-Aoki.pdf"},"version_id":"df5222e1-1928-4325-9f1b-7daa6ca87976"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"看護実習室","subitem_subject_scheme":"Other"},{"subitem_subject":"拭い取り式 ATP 計測法(A3法)","subitem_subject_scheme":"Other"},{"subitem_subject":"コンパクトドライ法","subitem_subject_scheme":"Other"},{"subitem_subject":"ぺたんチェック法","subitem_subject_scheme":"Other"},{"subitem_subject":"細菌や真菌のコロニー数","subitem_subject_scheme":"Other"},{"subitem_subject":"nursing practice room","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"wipe-type ATP measurement method (A3 method)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Compact Dry method","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Petan check stamp method","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"bacteria and fungi colony coun","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"看護技術演習で用いられるベッド周辺器具における消毒状況の拭い取り式ATP検出器および微生物培養による検証的研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"看護技術演習で用いられるベッド周辺器具における消毒状況の拭い取り式ATP検出器および微生物培養による検証的研究"},{"subitem_title":"Verifiable Study of the Status of Bed Peripheral Equipment Used in Nursing Practice Rooms after Disinfection Using a Wiping-type ATP Detector and Microbial Culture","subitem_title_language":"en"}]},"item_type_id":"3","owner":"4","path":["40"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-03-31"},"publish_date":"2023-03-31","publish_status":"0","recid":"155","relation_version_is_last":true,"title":["看護技術演習で用いられるベッド周辺器具における消毒状況の拭い取り式ATP検出器および微生物培養による検証的研究"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-06-28T07:22:18.617558+00:00"}